Operation Fyrite
INSIGHT
Plus Manual
66 0024-9487 Rev 2
4.4. The RUN Screen
The Fyrite
INSIGHT
Plus test data is located in the Run screen. By pressing
the RUN/HOLD button, you should hear the pump running and see the word
RUN at the upper-left hand corner of the display. The instrument is
continuously measuring and calculating the data that is shown in the Run
screen.
Press the RUN/HOLD button again. The pump should stop running and the
word HOLD should be shown at the upper-left hand corner of the display. The
instrument now shows the last measured and calculated data taken before the
instrument was placed in HOLD.
Use the UP (
) and DOWN (
) arrow buttons to scroll through the complete
list of measured and calculated values when the instrument is running or in the
HOLD mode.
Combustion Test Parameters NA Siegert
Oxygen O O
Carbon Monoxide CO CO
Excess Air EA Lambda
Efficiency Using Higher Heating Value Eff Eff
Carbon Dioxide CO CO
Setting for Maximum Carbon Dioxide in Flue Gas CO₂ Max
Stack Temperature T-STK T-STK
Ambient Air Temperature T-AIR T-AIR
Stack Loss qA
Efficiency Using Lower Heating Value Eta
Carbon Monoxide/Carbon Dioxide Ratio CO/CO
CO content referenced to an Oxygen percentage n CO(n) CO(n)
Average of 3 Manually Entered Smoke Numbers AVG SMOKE
Presence of Oil Derivatives (Manually Entered) OIL DERIVE
Boiler Temperature (Manually Entered) BOILER TEMP