Configuration Fyrite
INSIGHT
Plus Manual
34 0024-9487 Rev 2
Setup Menu Function
Smoke Number (Siegert only) is used to calculate and
display an average smoke value based on 3 smoke test
results that are entered by the user. A sample smoke
scale is shown below.
Perform 3 smoke tests then enter the results in the 3
smoke number parameters shown below.
Use the UP () and DOWN () arrow buttons to
highlight smoke number 1, 2, or 3, then press ENTER.
Use the LEFT () and RIGHT () arrow buttons to set
the smoke number (0-9) that most closely matches the
numerical value on your smoke scale for that sample.
Press ENTER when finished. The average smoke
number is displayed, and will be included on printouts.
WARNING: DO NOT use the Fyrite
INSIGHT
Plus to sample gas from an oil-
based combustion system without first
doing a smoke test and adjusting your
combustion process as needed. Smoke
test results of greater than 1 indicate
improper combustion, and demonstrate
the need for process adjustment. Only
use the Fyrite
INSIGHT
Plus to sample
flue gas AFTER the combustion process is
adjusted and the smoke test indicates a
smoke level of 0 or 1.