Fyrite
INSIGHT
Plus Manual Configuration
0024-9487 Rev 2 35
Setup Menu Function
Oil Derivative (Siegert only) specifies whether or not oil
derivatives were present during the smoke tests (see
page 34).
For incomplete combustion, oil derivatives present in
the sample can be precipitated onto the filter paper,
causing a color change in the smoke spot.
Use the UP () and DOWN () arrow buttons to select
the YES option if oil derivatives were present during
the smoke test. Otherwise select NO and press ENTER.
This information is included on printouts.
A boiler temperature (Siegert only) can be recorded
manually. Enter the boiler temperature as measured
by an external thermocouple.
Use the LEFT () and RIGHT () arrow buttons to
change position. Use the UP () and DOWN () arrow
buttons to scroll through numerals 0-9 for the selected
position. Press ENTER when finished.
This information is included on printouts.