Portable Emissions Analyzer Appendix
Teledyne Analytical Instruments 59
Appendix
Specifications
Sensors:
O
2
Measurement _____________________________
Sensor: Electrochemical, cell
Range: 0-20.9 vol.% O
2
Resolution: 0.1 vol. %
Accuracy: ± 0.2% vol.
Response Time (T97): <70 sec
CO2 Determination _____________________________
(Calculated from O2)
Sensor: none—calculated value
Display Range: 0-CO
2max
vol. %
Resolution: 0.1 vol. %
Accuracy: 0.2% vol.
Response time (T97): <70 sec
CO Measurement _____________________________
(with H2 compensation)
Sensor: Electrochemical, cell
Measurement Range: 0-4000 ppm
Resolution: 1 ppm
Accuracy: ± 5 ppm (up to 150 ppm)
± 5% of reading (up to 4000 ppm)
Response Time (T90): <60 sec
NO Measurement _____________________________
(Option)
Sensor: Electrochemical, electrochemical cell
Measurement Range 0-2000 ppm
Resolution: 1 ppm
Vista de pagina 70