Bacharach Tru Pointe Ultra HD Especificaciones Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
1 - 8 0 0 - 7 3 6 - 4 6 6 6 M y B a c h a r a c h . c o m
C o m b u s t i o n A n a l y z e r s
Combustion Analyzers
ECA 450
Industrial grade analyzer for both combustion efficiency and emissions
analysis
Generates and prints combustion efficiency and emissions reports
Supports modular, field replaceable, sensors for O
2
, NO, NO
2
, SO
2
,
CO and HC
Expandable in field - add or change sensors as your requirements change
Ideal for sampling and monitoring furnaces, boilers and other industrial
combustion equipment
Comes standard in hard case, 12” sample probe assembly with 15' of hose
and built-in printer
Unlike any other industrial grade combustion efficiency and environmental analyzer on the
market today, the ECA 450 conducts accurate combustion and emissions tests to ensure that
industrial equipment is burning efficiently and environmental regulations are being met.
MEASUREMENT RANGE
Primary/Ambient Air Temperature –4° to 999° F (-20 to 537˚C)
Stack Temperature –4° to 2400° F (-20 to 1316˚C)
Draft / Differential -27.7 to +27.7 in. of H
2
0
Oxygen (O
2
) 0.0 to 20.9%
Carbon Monoxide (CO) (H
2
comp) 0 to 4,000 ppm
Carbon Monoxide (CO) (High Range)* 4,001 to 80,000 ppm
Nitric Oxide (NO)* 0 to 3,500 ppm
Nitrogen Dioxide (NO
2
)* 0 to 500 ppm
Sulfur Dioxide (SO
2
)* 0 t0 4,000 ppm
Combustible Gases (HC)* 0 to 5.00% (application dependent)
SELECTABLE FUELS
Natural Gas, Propane, Coal, Wood, Kerosene, Oil #2, Oil #4, Oil #5,
Oil #6, Bagasse
CALCULATED RANGES RANGE
Combustion Efficiency 0.1 to 100.0%
Excess Air 0 to 250%
Carbon Dioxide (dry basis) 0 to fuel dependent maximum
NO
x
(NO
x
= NO + NO
2
) 0 to 4,000 ppm
NO
x
referenced to % O
2
0 to 17,000 ppm
CO referenced to % O
2
0 to 99,999 ppm
NO referenced to % O
2
0 to 14,900 ppm
NO
2
referenced to % O
2
0 to 2,100 ppm
SO
2
referenced to % O
2
0 to 17,000 ppm
ORDERING INFORMATION
0024-7221 ECA 450 Base Unit (O
2
, CO, Ts, Ta, DP)
0024-8400 ECA 450 with NO / NO
2
sensors and compact sample
conditioner
0024-8401 ECA 450 with NO, NO
2
and SO
2
sensors and
compact sample conditioner
OPTIONAL ACCESSORIES
0024-3024 24” Probe Assembly
0024-3025 36” Probe Assembly
0024-7224 Compact Sample Conditioner/Probe
0024-3035 24” High Temperature Probe Assembly
0024-3036 36” High Temperature Probe Assembly
0024-3037 48” High Temperature Probe Assembly
0024-1124 20 Ft. Hose Extension with sample, draft and
thermocouple lines
0024-1172 Water Trap/Filter Assembly (for Probe Assemblies)
0007-1644 Replacement Filters for Water Trap (pkg of 3)
0104-4027 Serial Cable DB 9M to DB 9F
0024-0980 Printer Paper (5 rolls)
OTHER SPECIFICATIONS
Power Universal AC adapter and an internal battery
pack. Adapter will accept input voltages
from 100 to 240V. Fully charged battery pack
provides a minimum of 8 hrs of operation
Size 13.5” H x 18.5” W x 9” D
(34.3 cm x 47 cm x 22.9 cm)
Weight 25 lbs (11.34 kg)
Memory Stores over 1000 test records
Display 160 x 160 (2.5 in. x 2.5 in.) Graphic Liquid
Crystal Display
Warranty 1 year (does not include probe)
* Optional
Two pumps are included. The first pump supplies gas sample to the
sensors. The second pump supplies fresh air to purge the low range CO
sensor when CO levels exceed 4000 ppm. Probe includes a standard probe
and hose assembly equipped with a water trap, particulate filter, probe
stop, 15 feet of hose and 12-inch probe tube.
www.actoolsupply.com
www.actoolsupply.com
Vista de pagina 5
1 2 3 4 5 6 7 8 9 10 11 ... 47 48