18
1 - 8 0 0 - 7 3 6 - 4 6 6 6 • M y B a c h a r a c h . c o m
Leak DetectorsLeak Detectors
3015-0456 • Refrigerant leak detector with automatic and manual adjustment
• Detects all CFC, HFC and HCFC refrigerants
• AC powered (120 VAC only)
• Performance exceeds SAE J1627
• Supplied with leak reference bottle, probe tip and filter kit
3015-0627 • Refrigerant leak detector with dual power source
that detects all CFC, HFC and HCFC
• Manual or automatic zero balance control
• Pass / fail test mode
• Unique sensor calibration system
• 3 sensitivity modes
• Powered by a rechargable battery
• Pinpoints both small and large leaks
H-10PM
SENSING TECHNOLOGY
Refrigerant Sensor Positive Ion Emission Heated Diode
GASES DETECTED
Refrigerants All CFC, HCFC and HFC refrigerants
RESPONSE TIME
1 second
ALARM SENSITIVITY
R-134a Small - 0.1 oz / year
Medium - 0.5 oz / year
Large - 2.0 oz / year
R12 Small - 0.05 oz / year
Medium - 0.1 oz / year
Large - 1.0 oz / year
Accuracy Exceeds SAE J1627
LEAK ALARM
Audible and visual Visible LED lamp Audible alarm and visible
neon lamp
OTHER SPECIFICATIONS
Power 12 VDC - internal rechargeable 120 VAC 50/60 Hz
sealed lead acid battery
120 - 240 VAC universal battery charger
to charge or run unit continuously
Size 5.5” x 10.5” x 8.5” 2.5” x 4.5” x 8.5”
(14 cm x 26.67 cm x 21.6 cm) (6.35 x 11.43 x 21.6 cm)
Weight 5 lbs. (2.27 kg) 3 lbs. (1.36 kg)
Probe Length 4.5 ft (1.37 m) 4.5 ft (1.37 m)
CERTIFICATIONS
CE-Mark
H-10PM H-10G
ORDERING INFORMATION
3015-0627 H-10PM All-In-One Leak Detector
3015-0456 H-10G Standard Leak Detector
OPTIONAL ACCESSORIES
3015-0119 Battery Charger for H-10PM,
120 - 240 VAC Universal (will charge
or run unit)
3015-0103 Battery for H-10PM
3015-0326 14” Flexible Probe
3015-0638 Standard Probe Assembly for H10G
3015-0486 Replacement Sensor
3015-0864 Leak Reference Bottle
3015-0641 Clear Probe Tip
3015-0781 Tune-Up Kit
3015-0680 Rubber Probe Tip
3015-0880 Probe w/LED for H-10PM
H-10G