Combustion Gas Analyzer Configuration and Operation Manual Instruction 0024-9486 Revision 2 December 27, 2012 Product
Overview Fyrite InTech Manual 4 0024-9486 Rev 2 Feature North American (NA) versus Siegert (S) Configurations Countries Typical North American
Fyrite InTech Manual Overview 0024-9486 Rev 2 5 1.6. Components
Overview Fyrite InTech Manual 6 0024-9486 Rev 2
Fyrite InTech Manual Overview 0024-9486 Rev 2 7 1.7. Features • Sensors (pp 51, 60) o Field-replaceable electrochemical sensors (O2 and B-SM
Overview Fyrite InTech Manual 8 0024-9486 Rev 2 1.8. Combustion Test Process Overview FUNCTION ...
Fyrite InTech Manual Overview 0024-9486 Rev 2 9 NOTE: The North American (NA) configuration of Fyrite InTech computes and displays the c
Overview Fyrite InTech Manual 10 0024-9486 Rev 2
Fyrite InTech Manual Overview 0024-9486 Rev 2 11 1.10. Specifications Specification Description Temperature Storage: -20° to 50° C ( -4° to
Overview Fyrite InTech Manual 12 0024-9486 Rev 2 Specification Description Power Supply Options Batteries (4 AA) Type: Disposable Alkaline (In
Fyrite InTech Manual Setup 0024-9486 Rev 2 13 Section 2. Setup 2.1. Connecting the Probe and Thermocouple A rigid stainless steel probe with
Fyrite InTech Manual ii 0024-9486 Rev 2 WARRANTY POLICY Bacharach, Inc. warrants to Buyer that at the time of delivery this product will be free
Setup Fyrite InTech Manual 14 0024-9486 Rev 2 2.2. Front Panel Buttons Button Description • Powers the analyzer ON and OFF. Hold this button
Fyrite InTech Manual Setup 0024-9486 Rev 2 15 2.3. Power Options You use the PWR button to turn on the Fyrite InTech. Power options includ
Setup Fyrite InTech Manual 16 0024-9486 Rev 2 NOTE: A Set Clock error message will be displayed if the instrument is without power for an
Fyrite InTech Manual Configuration 0024-9486 Rev 2 17 Section 3. Configuration 3.1. Menu Structure Overview NOTE: The Fyrite InTech may b
Configuration Fyrite InTech Manual 18 0024-9486 Rev 2 3.3. Main Menu Display the Main Menu by pressing the F2 key. Note that features and item
Fyrite InTech Manual Configuration 0024-9486 Rev 2 19 3.4. Select Fuel Menu Select Fuel Function Select the combustion fuel from the fuel li
Configuration Fyrite InTech Manual 20 0024-9486 Rev 2 3.5. Ambient CO Menu (Siegert Only) Ambient CO Function Access the Ambient CO Menu (Sie
Fyrite InTech Manual Configuration 0024-9486 Rev 2 21 Ambient CO Function The test results can be printed by pressing F1 and saved to memory
Configuration Fyrite InTech Manual 22 0024-9486 Rev 2 3.6. Memory Options Menu Memory Options Function Access the Memory Directory. This dire
Fyrite InTech Manual Configuration 0024-9486 Rev 2 23 Memory Options Function Print Average (Siegert Only) displays the memory directory wi
Fyrite InTech Manual 0024-9486 Rev 2 iii NOTICE Product improvements and enhancements are continuous; therefore the specifications and informat
Configuration Fyrite InTech Manual 24 0024-9486 Rev 2 3.7. Setup Menu Setup Menu Function Access Temperature Units (°C or °F) to be used by t
Fyrite InTech Manual Configuration 0024-9486 Rev 2 25 Setup Menu Function WARNING: DO NOT use the Fyrite InTech to sample gas f
Configuration Fyrite InTech Manual 26 0024-9486 Rev 2 Setup Menu Function A boiler temperature (Siegert only) can be recorded manually. Ent
Fyrite InTech Manual Configuration 0024-9486 Rev 2 27 Setup Menu Function NOTE: The presence of AM or PM after the time on the Set Cl
Configuration Fyrite InTech Manual 28 0024-9486 Rev 2 Setup Menu Function Provides an interface for entering user identification information u
Fyrite InTech Manual Configuration 0024-9486 Rev 2 29 Setup Menu Function The Language Selection option allows the user to choose a language
Configuration Fyrite InTech Manual 30 0024-9486 Rev 2 Setup Menu Function Provides a list from which to select an inactivity (key press) timeo
Fyrite InTech Manual Configuration 0024-9486 Rev 2 31 Setup Menu Function Date format (North American Configuration only) Provides a list fro
Configuration Fyrite InTech Manual 32 0024-9486 Rev 2 Setup Menu Function Provides a list from which the user may select the desired method fo
Fyrite InTech Manual Configuration 0024-9486 Rev 2 33 Setup Menu Function IMPORTANT: Changing this setting resets several confi
Fyrite InTech Manual iv 0024-9486 Rev 2
Configuration Fyrite InTech Manual 34 0024-9486 Rev 2 3.8. Calibration Menu Calibration Menu Function Calibration is performed by applying kn
Fyrite InTech Manual Configuration 0024-9486 Rev 2 35 3.9. Diagnostics Menu Diagnostics Menu Function Displays time metrics for pump use and
Configuration Fyrite InTech Manual 36 0024-9486 Rev 2 Diagnostics Menu Function In this case: • Note the 3-digit date code on the new sensor •
Fyrite InTech Manual Configuration 0024-9486 Rev 2 37 Diagnostics Menu Function NOTE: If either of the entered values is incorrect, the stat
Fyrite InTech Manual Operation 0024-9486 Rev 2 38 Section 4. Operation 4.1. Prerequisites Before beginning your combustion test, verify the f
Fyrite InTech Manual Operation 0024-9486 Rev 2 39 Example Forced Air Furnace Example Hot Water Tank For atmospheric burner or gravity vent
Operation Fyrite InTech Manual 40 0024-9486 Rev 2 Example 90% Efficiency Condensing Furnace Example 80% Efficiency Fan Assist or Power Vented Fu
Fyrite InTech Manual Operation 0024-9486 Rev 2 41 4.3. Combustion Testing Process WARNING: The Fyrite InTech calculates combustion paramet
Operation Fyrite InTech Manual 42 0024-9486 Rev 2 Step Example Combustion Testing Procedure purge component that clears the sensors of combusti
Fyrite InTech Manual Operation 0024-9486 Rev 2 43 Combustion Test Parameters NA Siegert Oxygen O₂ O₂ Carbon Monoxide CO CO Excess Air E
Fyrite InTech Manual Table of Contents 0024-9486 Rev 2 v Table of Contents Section 1. Overview ...
Operation Fyrite InTech Manual 44 0024-9486 Rev 2 Combustion Equations are shown below. Fyrite InTech provides three lines of 20 characters f
Fyrite InTech Manual Operation 0024-9486 Rev 2 45 IR Communications Settings: Baud Rate: 9600 Data Bits: 8 Stop Bits: 1 Parity: None Pr
Operation Fyrite InTech Manual 46 0024-9486 Rev 2 Fyrite InTech can be setup to include a custom logo on printouts. Logos are loaded into th
Fyrite InTech Manual Operation 0024-9486 Rev 2 47 4.7. PC Interface and Fyrite User Software A PC with Fyrite User Software (FUS) installed
Fyrite InTech Manual Calibration and Maintenance 0024-9486 Rev 2 48 Section 5. Calibration and Maintenance 5.1. Serviceability The instrument
Fyrite InTech Manual Calibration and Maintenance 0024-9486 Rev 2 49 5.2.1. Equipment Required • Alcohol • Aerosol Can of Automotive Carburetor
Calibration and Maintenance Fyrite InTech Manual 50 0024-9486 Rev 2 5.3. Water Trap and Filter Replacement
Fyrite InTech Manual Calibration and Maintenance 0024-9486 Rev 2 51 5.4. O2 and/or CO Sensor Replacement NOTE: The O2 sensor life is approxi
Calibration and Maintenance Fyrite InTech Manual 52 0024-9486 Rev 2 5.4.3. O2 Sensor Replacement Procedure Follow the procedure below for O2 se
Fyrite InTech Manual Calibration and Maintenance 0024-9486 Rev 2 53 Step CO Sensor Replacement Procedure in the diagram below, then twisting
Table of Contents Fyrite InTech Manual vi 0024-9486 Rev 2 4.7. PC Interface and Fyrite User Software ...
Calibration and Maintenance Fyrite InTech Manual 54 0024-9486 Rev 2 NOTE: Bacharach offers a convenient Exchange Program (where available) tha
Fyrite InTech Manual Calibration and Maintenance 0024-9486 Rev 2 55 Step T-STACK Calibration Procedure "Measured" is the curren
Calibration and Maintenance Fyrite InTech Manual 56 0024-9486 Rev 2 Step T-STACK Calibration Procedure 7 Wait until the Measured reading stabi
Fyrite InTech Manual Calibration and Maintenance 0024-9486 Rev 2 57 Step Manual CO Zero Procedure 5.6.3. CO Sensor Span Procedure Step CO
Calibration and Maintenance Fyrite InTech Manual 58 0024-9486 Rev 2 5.7. T-Ref Sensor Calibration The T-Ref sensor is located inside the in
Fyrite InTech Manual Troubleshooting 0024-9486 Rev 2 59 Section 6. Troubleshooting 6.1. Error and Warning Messages Message Description T-STK
Troubleshooting Fyrite InTech Manual 60 0024-9486 Rev 2 Message Description instrument. • Messages will indicate which sensors are in error.
Fyrite InTech Manual Troubleshooting 0024-9486 Rev 2 61 Part Number Description 0024-1484 CO Sensor Cap 0024-1458 CO Sensor Base 0024-9486
Troubleshooting Fyrite InTech Manual 62 0024-9486 Rev 2 6.4. Instrument Identification A label on the back of the instrument provides the foll
Fyrite InTech Manual Declaration of Conformity 0024-9486 Rev 2 63 Declaration of Conformity The manufacturer of the products covered by thi
Fyrite InTech Manual Overview 0024-9486 Rev 2 1 Section 1. Overview 1.1. Introduction Thank you for investing in a Bacharach Fyrite InTech
Declaration of Conformity Fyrite InTech Manual 64 0024-9486 Rev 2
Fyrite InTech Manual 0024-9486 Rev 2 65
Fyrite InTech Manual 0024-9486 Rev 2 66 World Headquarters 621 Hunt Valley Circle, New Kensington, Pennsylvani
Overview Fyrite InTech Manual 2 0024-9486 Rev 2 CAUTION: This analyzer is not intended to be used on a continuous basis. CAUTION: Do not st
Fyrite InTech Manual Overview 0024-9486 Rev 2 3 1.4. Product Overview The Fyrite InTech is a portable hand-held combustion analyzer for us